WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
UNVENTED (VENT-FREE) GAS FIREPLACE INSERT
OWNER’S OPERATION AND INSTALLATION MANUAL
VI33NRB AND VI33PRB
REMOTE READY GAS FIREPLACE INSERT
®
Shown with GS38 Surround Kit and
G8010 Brick Liner Accessories
PFS
®
US
Przeglądanie stron 0
1 2 3 4 5 6 ... 35 36

Podsumowanie treści

Strona 1 - VI33NRB AND VI33PRB

For more information, visit www.fmiproducts.com WARNING: If the information in this manual is not followed exactly, a re or explosion may result caus

Strona 2 - TABLE OF CONTENTS

www.fmiproducts.com113195-01K10INSTALLING SURROUND KIT (GS38 OR GS43) CAUTION: Close masonry replace damper securely be-fore installing replac

Strona 3 - Continued

www.fmiproducts.com113195-01K 11Figure 8 - Attaching Top Surround PanelFigure 9 - Attaching Side Panels to Top PanelTop Surround PanelTop PanelSide Pa

Strona 4

www.fmiproducts.com113195-01K12Mantel Clearances for Insert InstallationIf there is a mantel above masonry replace, you must meet minimum clearance b

Strona 5 - UNPACKING

www.fmiproducts.com113195-01K 13INSTALLATIONContinuedFor propane/LP units, installer must supply an external regulator. External regulator will re

Strona 6 - PRODUCT FEATURES

www.fmiproducts.com113195-01K142. Remove screws that attach log base assembly to replace insert (see Figure 15). Carefully lift up log base ass

Strona 7 - FOR HEATER LOCATION

www.fmiproducts.com113195-01K 15INSTALLATIONContinued4. Check all joints of gas supply piping sys-tem. Apply a noncorrosive leak detection uid to al

Strona 8 - VENTILATION AIR

www.fmiproducts.com113195-01K1635"17 1/4"26 1/4"Figure 20 - Rough Opening for Installing in Masonry Fireplace3. Install gas piping to

Strona 9

www.fmiproducts.com113195-01K 17INSTALLATIONContinuedFigure 24 - Installing Log Set (Top View)Figure 25 - Installing ScreenNotchesScrews for Mounting

Strona 10 - INSTALLATION

www.fmiproducts.com113195-01K18INSTALLATIONContinuedOPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES (HRC100 Series and HRC200 Series)Installing

Strona 11

www.fmiproducts.com113195-01K 19OPERATIONFOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol-low these instructions exactly, a re or

Strona 12

www.fmiproducts.com113195-01K2SAFETYTABLE OF CONTENTSSafety ... 2Local Codes...

Strona 13

www.fmiproducts.com113195-01K20OPERATIONContinued7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot

Strona 14

www.fmiproducts.com113195-01K 21OPERATIONContinuedNote: The burner may light if hand-held re-mote was on when selector switch was last turned off.

Strona 15

www.fmiproducts.com113195-01K22Safety FeaturesWhen away from home for an extended period of time or as a child safety feature to prevent accidental i

Strona 16

www.fmiproducts.com113195-01K 23BURNER FLAME PATTERNFigure 38 shows a correct burner ame pat-tern. Figure 39 shows an incorrect burner flame p

Strona 17

www.fmiproducts.com113195-01K241. Shut off unit, including pilot. Allow unit to cool for at least thirty minutes.2. Inspect burner, pilot and prim

Strona 18

www.fmiproducts.com113195-01K 25TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualied service person should service

Strona 19 - OPERATION

www.fmiproducts.com113195-01K26POSSIBLE CAUSE1. Control knob not fu lly pressed in2. Control knob not pressed in long enough3. Equipment shutoff va

Strona 20

www.fmiproducts.com113195-01K 27POSSIBLE CAUSE1. Not enough air2. Gas regulator defective3. Residues from manufac-turing processes and logs curin

Strona 21

www.fmiproducts.com113195-01K28 WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical sw

Strona 22 - INSPECTING BURNERS

www.fmiproducts.com113195-01K 29SPECIFICATIONSVI33PRB• Rating: 22,000/33,000 Btu/Hr• Gas Type: Propane/LP Gas• Ignition: Piezo• Pressure Manifold:

Strona 23 - CLEANING AND MAINTENANCE

www.fmiproducts.com113195-01K 3 DANGER: Carbon monoxide poisoning may lead to death!Carbon Monoxide Poisoning: Early signs of carbon monoxide pois

Strona 24 - WIRING DIAGRAMS

www.fmiproducts.com113195-01K30PARTSMODELS VI33NRB AND VI33PRB 17 8 12 26 7 6 4 3 2 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27

Strona 25 - TROUBLESHOOTING

www.fmiproducts.com113195-01K 31PARTSThis list contains replaceable parts used in your replace insert. When ordering parts, follow the instructions l

Strona 26

www.fmiproducts.com113195-01K32PARTSFIREPLACE INSERT MODELS VI33NRB AND VI33PRB1114881493149921710141251413152342761716181920212222231424251426

Strona 27

www.fmiproducts.com113195-01K 33PARTSFIREPLACE INSERT MODELS VI33NRB AND VI33PRBThis list contains replaceable parts used in your replace insert. Whe

Strona 28

www.fmiproducts.com113195-01K34ACCESSORIESPurchase these accessories from your local dealer. If they can not supply these acces-sories, either

Strona 29 - SPECIFICATIONS

www.fmiproducts.com113195-01K 35WALL-MOUNT THERMOSTAT SWITCH - GWMT1For all models. The desired comfort setting can be selected on the wall thermostat

Strona 30 - Note: Items 27

113195-01Rev. K09/09WARRANTYKEEP THIS WARRANTYFMI PRODUCTS, LLC LIMITED WARRANTIESNew ProductsStandard Warranty: FMI PRODUCTS, LLC warrants this new p

Strona 31 - PARTS AVAILABLE — NOT SHOWN

www.fmiproducts.com113195-01K4SAFETYContinued1. This appliance is only for use with the type of gas indicated on rating plate. This appliance

Strona 32 - 113195-01K32

www.fmiproducts.com113195-01K 5LOCAL CODESPRODUCT IDENTIFICATIONFigure 1 - Log Base AssemblyFigure 2 - Fireplace InsertTop Louver AssemblyFirebox Hood

Strona 33 - 113195-01K 33

www.fmiproducts.com113195-01K6REMOTE CONTROL ACCESSORIESPRODUCT FEATURESThere are four optional remote controls that can be purchased separat

Strona 34 - ACCESSORIES

www.fmiproducts.com113195-01K 7a. walls and ceilings exposed to the out-side atmosphere have a continuous water vapor retarder with a rating

Strona 35

www.fmiproducts.com113195-01K8AIR FOR COMBUSTION AND VENTILATIONContinuedVentilation Air From OutdoorsProvide extra fresh air by using ventilati

Strona 36 - WARRANTY

www.fmiproducts.com113195-01K 9 WARNING: Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, c