OWNER’S OPERATION AND INSTALLATION MANUAL
DIRECT-VENT GAS FIREPLACE HEATER
®
®
VDVF36PN/PP (PENINSULA) AND VDVF36STN/STP (SEE THRU)
This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not
prohibited by state or local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS :
Do not try to light any appliance.
Do not touch any electrical switch;
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
SAVE THIS BOOK
This book is valuable. In addition to instructing
you on how to install and maintain your appli-
ance, it also contains information that will
enable you to obtain replacement parts or
optional accessory items when needed. Keep
it with your other important papers.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance to this appliance can
cause injury or property damage.
Refer to this manual. For assistance
or additional information consult a
qualified installer, service agency,
or the gas supplier.
CHECK LOCAL CODES PRIOR TO INSTALLATION
WARNING: If the information in these instruc-
tions is not followed exactly, a fire or explosion
may result causing property damage, personal
injury, or loss of life.
WARNING: This Direct-Vent Gas
Fireplace Heater series is intended
for use with Natural or Propane/LP
gas only. Do not attempt to burn any
solid fuels in these appliances.
(Peninsula
Shown)
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - (Peninsula

Save this manual for future reference.OWNER’S OPERATION AND INSTALLATION MANUALDIRECT-VENT GAS FIREPLACE HEATER®®VDVF36PN/PP (PENINSULA) AND VDVF36STN

Strona 2

10105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®VENTINGINSTALLATIONContinuedUPFigure 21 - Horizontal Termination Configuration for

Strona 3

11105706OWNER’S MANUALVENTINGINSTALLATIONContinuedVenting with Two 90° ElbowsVertical (V) Horizontal (H1) +Horizontal (H2)5' min. 4' max.6&a

Strona 4

12105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®4. Connect a section of pipe and extendup through the hole.Note: If an offset is n

Strona 5 - PREPARATION

13105706OWNER’S MANUALVENTINGINSTALLATIONContinuedContinuedFigure 26 - Cathedral Ceiling SupportBox InstallationNon-hardening Mastic under alledges of

Strona 6

14105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®Vertical VentingV = 30' max.Figure 31 - Vertical Rigid VentingConfiguration W

Strona 7

15105706OWNER’S MANUALVENTINGINSTALLATIONContinuedHIGH ALTITUDEINSTALLATIONYour Vanguard direct-vent fireplace hasbeen AGA tested and approved for ele

Strona 8

16105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®Figure 33 - Wall Switch Wiring DiagramOPTIONAL WIRELESS HAND-HELD REMOTE CONTROL(G

Strona 9

17105706OWNER’S MANUALINSTALLATIONContinuedInstalling 9-Volt Alkaline Battery inHand-Held Remote Control Unit1. Remove battery cover on back of re-mot

Strona 10 - VDVF36P and VDVF36ST Series

18105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®INSTALLATIONContinuedINSTALLING LOG SETBefore proceeding, make sure the gas con-tr

Strona 11 - OWNER’S MANUAL

19105706OWNER’S MANUALINSTALLATIONContinued WARNING: Improper installa-tion, adjustment, alteration, ser-vice, or maintenance can causeinjury or prope

Strona 12

2105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®FRONT VIEW30(76cm)(Opening)23 5/8 (60cm)25 (64cm)RIGHT SIDE22 5/8(57cm)43 1/8 (110c

Strona 13

20105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®OPERATINGGUIDELINES ANDMAINTENANCEINSTRUCTIONSWhen lit for the first time, the app

Strona 14

21105706OWNER’S MANUALTO TURN OFF GASTO APPLIANCE1. Turn off the wall switch.2. Turn off all electric power to the ap-pliance if service is to be perf

Strona 15

22105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®1. After lighting, let pilot flame burn forabout one minute. Turn control knobto O

Strona 16

23105706OWNER’S MANUALThermocoupleIncomingMainGasSupplyPiezo IgnitorControlValveVariable SpeedControl* Remote ControlElectrical Rating:120v, 60Hz, 0.

Strona 17

24105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®TROUBLESHOOTINGOBSERVED PROBLEMPilot will not lightNo gas to burner, although wall

Strona 18

25105706OWNER’S MANUALwww.desatech.comTROUBLESHOOTINGContinuedPOSSIBLE CAUSE1. Ignitor electrode not connected to igni-tor cable2. Ignitor cable pinch

Strona 19

26105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®OBSERVED PROBLEMBurner does not light after pilot is litDelayed ignition burnerBur

Strona 20

27105706OWNER’S MANUALTROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any e

Strona 21

28105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®ACCESSORIESRECEIVER AND HAND-HELDON/OFF REMOTE CONTROLKIT - GHRCFor all models. Al

Strona 22

29105706OWNER’S MANUALGAS CONTROL VALVENatural - 105882-01 (25699)Propane/LP - 105882-02 (25700)If in need of replacing, have a qualifiedtechnician re

Strona 23

3105706OWNER’S MANUALModels VDVF36PN/PP series are three-sided direct-vent gas fireplace heaters witha sealed combustion chamber. ModelsVDVF36STN/STP

Strona 24

LIMITED WARRANTYDIRECT-VENT FIREPLACEDESA International warrants this product to be free from defects in materials and components for four (4) years f

Strona 25

4105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®FRAMINGOnce the final location has been determined,observing height clearances for

Strona 26

5105706OWNER’S MANUALFigure 7 - Rough Opening for InstallingPeninsula Fireplace39 3/4"(1010mm)Min.40 1/2"(1029mm)23 5/8"(600mm)39 3/4&q

Strona 27

6105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®FixedClosedOpenableFixedClosedOpenableVVVVVVVVXXVXGGJFBBKNHIANELDBMACBVVAGGBTERMINA

Strona 28

7105706OWNER’S MANUAL WARNING: Read all instruc-tions completely and thoroughlybefore attempting installation.Failure to do so could result inserious

Strona 29

8105706DIRECT-VENT GAS FIREPLACE HEATERVDVF36P and VDVF36ST Series®INSTALLATION FORHORIZONTAL TERMINATION1. Determine the route your horizontalventing

Strona 30 - WARRANTY INFORMATION

9105706OWNER’S MANUALUPUPVENTINGINSTALLATIONContinued(FramingDetail)10"(254mm)10"(254mm)7 1/2"(190mm)Vent OpeningCombustible WallVent O

Komentarze do niniejszej Instrukcji

Brak uwag