OPERATING INSTRUCTIONS
for the
HERCULITO
100 Amperes True DC
Digital Micro Ohm Meter
Vanguard Instruments Company
1520 S. Hellman Avenue
Ontario, California 91761
TEL: (909) 923-9390 Nov 2006
FAX: (909) 923-9391 Rev. 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 16 17

Podsumowanie treści

Strona 1 - Vanguard Instruments Company

OPERATING INSTRUCTIONSfor theHERCULITO100 Amperes True DCDigital Micro Ohm MeterVanguard Instruments Company1520 S. Hellman AvenueOntario, California

Strona 2

Herculito Operating Procedures94.0 OPERATING VOLTAGESThe Herculitp operates with voltages between 90-240Vac, 50/60Hz.5.0 CABLE CONNECTIONThe Herculi

Strona 3

Herculito Operating Procedures106.0 OPERATING THE HERCULITOThe Herculito is operated with one control knob. The operator turns the control knob to sc

Strona 4

Herculito Operating Procedures116.1.3 Run Test ProcedureTo run a test, turn the control knob until RUN TEST appears on the display, then press thecont

Strona 5

Herculito Operating Procedures12From the Main Menu another test can be run. If all test have been completed, turn off power tothe Herculito, disconne

Strona 6

Herculito Operating Procedures136.1.7 Herculito Cal CheckThe purpose of the Calibration Check is to verify that the Herculito is operating withinaccep

Strona 7 - 2.0 HERCULITO SPECIFICATIONS

Herculito Operating Procedures14The following menus will be displayed when the Herculito is going through the CalibrationCheckCal Check in ProgressZer

Strona 8 - 3.0 CONTROL AND DISPLAY

Herculito Operating Procedures156.1.8 Display Previous ResultsThe purpose of this procedure is to let an operator view the last 3 readings stored in t

Strona 9

Herculito Operating Procedures161520 South Hellman Avenue. Ontario, CA 91761, USAPhone 909-923-9390 Fax 909-923-9391Web site: http//www.vanguard-inst

Strona 10

Herculito Operating Procedures1SAFETY SUMMARYSAFETY WARNINGS AND CAUTIONSThis device shall be used only by trained operators.All circuit breakers unde

Strona 11 - <RUN TEST>

Herculito Operating Procedures2Table of Contents1.0 INTRODUCTION ...

Strona 12 - Remaining burn-in

Herculito Operating Procedures3Table of FiguresFigure 1 Herculito Current Cable ...

Strona 13

Herculito Operating Procedures41.0 INTRODUCTION1.1 ApplicabilityThis manual applies to the Model Herculito, made by Vanguard Instruments Company.1.2

Strona 14 - <START CAL CHK>

Herculito Operating Procedures51.4 Furnished Test AccessoriesThe Herculito is supplied with two 45-foot #8 AWG test cables with heavy-duty alligatorcl

Strona 15

Herculito Operating Procedures62.0 HERCULITO SPECIFICATIONSHerculito specifications and leading particulars are listed in Table 1.Table 1 Herculito

Strona 16

Herculito Operating Procedures73.0 CONTROL AND DISPLAY3.1 Herculito Front PanelThe Herculito controls and displays are shown in the control-panel ill

Strona 17 - Herculito Nov 2006

Herculito Operating Procedures8Table 2 Functional Description of Herculito Controls and DisplayFigure 1Index #Adjacent Panel Marking Functional Descr